1.
J Steroid Biochem Mol Biol ; 231: 106318, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37169270

RESUMO

Ninety archived human serum samples from the Vitamin D External Quality Assessment Scheme (DEQAS) were analyzed using a reference measurement procedure (RMP) based on isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS) for the determination of 24,25-dihydroxyvitamin D3 [24,25(OH)2D3]. These 24,25(OH)2D3 results, in conjunction with concentration values assigned using RMPs for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3], provide a valuable resource for assessing the accuracy of measurements for 24,25(OH)2D3 and for investigating the relationship between 24,25(OH)2D3 and 25(OH)D3. Results for 24,25(OH)2D3 using the RMP were compared to DEQAS consensus values demonstrating that the consensus values were not sufficient to assess the accuracy of measurements among different laboratories and methods. A multivariable regression analysis approach using historical DEQAS consensus values for various total 25(OH)D assays was used to assess the contribution of 24,25(OH)2D3 concentration on the assay response. The response of several ligand binding assays for total 25(OH)D was shown to be impacted by the presence of 24,25(OH)2D3.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Humanos , Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Vitaminas , Calcifediol , 24,25-Di-Hidroxivitamina D 3
2.
Anal Bioanal Chem ; 414(1): 333-349, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34432104

RESUMO

An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays used for the determination of serum total 25-hydroxyvitamin D (25(OH)D), which is the sum of 25-hydroxyvitamin D2 (25(OH)D2) and 25-hydroxyvitamin D3 (25(OH)D3). A set of 50 single-donor samples was assigned target values for concentrations of 25(OH)D2, 25(OH)D3, 3-epi-25-hydroxyvitamin D3 (3-epi-25(OH)D3), and 24R,25-dihydroxyvitamin D3 (24R,25(OH)2D3) using isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 1 includes results from 14 laboratories using 14 custom LC-MS/MS assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 53% of the LC-MS/MS assays met the VDSP criterion of mean % bias ≤ |±5%|. For the LC-MS/MS assays not meeting the ≤ |±5%| criterion, four assays had mean % bias of between 12 and 21%. Based on multivariable regression analysis using the concentrations of the four individual vitamin D metabolites in the 50 single-donor samples, the performance of several LC-MS/MS assays was found to be influenced by the presence of 3-epi-25(OH)D3. The results of this interlaboratory study represent the most comprehensive comparison of LC-MS/MS assay performance for serum total 25(OH)D and document the significant impact of the lack of separation of 3-epi-25(OH)D3 and 25(OH)D3 on assay performance, particularly with regard to mean % bias.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 25-Hidroxivitamina D 2 , Cromatografia Líquida/métodos , Padrões de Referência , Espectrometria de Massas em Tandem/métodos , Vitamina D/análogos & derivados
3.
Anal Bioanal Chem ; 414(1): 351-366, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34435207

RESUMO

An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25-hydroxyvitamin D3 [3-epi-25(OH)D3], and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 50% of the ligand binding assays achieved the VDSP criterion of mean % bias ≤ |± 5%|. For the 13 unique ligand binding assays evaluated in this study, only 4 assays were consistently within ± 5% mean bias and 4 assays were consistently outside ± 5% mean bias regardless of the laboratory performing the assay. Based on multivariable regression analysis using the concentrations of individual vitamin D metabolites in the 50 single-donor samples, most assays underestimate 25(OH)D2 and several assays (Abbott, bioMérieux, DiaSorin, IDS-EIA, and IDS-iSYS) may have cross-reactivity from 24R,25(OH)2D3. The results of this interlaboratory study represent the most comprehensive comparison of 25(OH)D ligand binding assays published to date and is the only study to assess the impact of 24R,25(OH)2D3 content using results from a reference measurement procedure.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 25-Hidroxivitamina D 2 , Cromatografia Líquida , Ligantes , Padrões de Referência , Vitamina D/análogos & derivados
4.
Anal Bioanal Chem ; 414(2): 1015-1028, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34750644

RESUMO

The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at -40 °C prior to distribution and the participants are instructed to store the samples frozen at -20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC-MS/MS assays, the differences in the results for the ambient- and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays.


Assuntos
Congelamento , Vitamina D/análogos & derivados , Vitamina D/sangue , Cromatografia Líquida/métodos , Humanos , Espectrometria de Massas em Tandem/métodos
5.
Anal Bioanal Chem ; 413(20): 5067-5084, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34184102

RESUMO

An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.


Assuntos
Sociedades Médicas/normas , Vitamina D/análogos & derivados , Vitamina D/química , Humanos , Padrões de Referência , Manejo de Espécimes , Vitamina D/sangue
6.
J Steroid Biochem Mol Biol ; 212: 105917, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34010687

RESUMO

An intralaboratory study assessing assay variability and bias for determination of serum total 25-hydroxyvitamin D [25(OH)D] was conducted by the Vitamin D Standardization Program (VDSP). Thirteen assays for serum total 25(OH)D were evaluated in a single laboratory including 11 unique immunoassays and one liquid chromatography - tandem mass spectrometry (LC-MS/MS) assay. Fifty single-donor serum samples, including eight samples with high concentrations of 25(OH)D2 (> 30 nmol/L), were assigned target values for 25(OH)D2 and 25(OH)D3 using reference measurement procedures (RMP). Using four replicate measurements for each sample, the mean total percent coefficient of variation (%CV) and mean % bias from the target values were determined for each assay using the 50 single-donor samples and a 42-sample subset, which excluded 8 high 25(OH)D2 concentration samples, and compared with VDSP performance criteria of ≤ 10 % CV and ≤ ±5 % mean bias. All 12 assays achieved the performance criterion for % CV, and 9 of the 12 assays were within ≤ ±5 % mean bias. The Fujirebio Inc. assay exhibited the lowest %CV and highest percentage of individual measurements within ≤ ±5 % mean bias. Ten immunoassays exhibited changes in response due to the high 25(OH)D2 samples with Abbott, Biomérieux, DiaSorin, DIAsource, and IDS-iSYS assays having the largest deviations. The Fujirebio Inc. and Beckman Coulter assays were only minimally affected by the presence of the high 25(OH)D2 samples. Samples with high concentrations of 25(OH)D2 provided a critical performance test for immunoassays indicating that some assays may not have equal response or recovery for 25(OH)D2 and 25(OH)D3.


Assuntos
Bioensaio/normas , Imunoensaio/normas , Vitamina D/análogos & derivados , Vitaminas/sangue , Viés , Cromatografia Líquida , Humanos , Laboratórios , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Vitamina D/sangue
7.
Clin Chem Lab Med ; 59(4): 671-679, 2021 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-33098630

RESUMO

OBJECTIVES: Matrix differences among serum samples from non-pregnant and pregnant patients could bias measurements. Standard Reference Material 1949, Frozen Human Prenatal Serum, was developed to provide a quality assurance material for the measurement of hormones and nutritional elements throughout pregnancy. METHODS: Serum from non-pregnant women and women in each trimester were bottled into four levels based on pregnancy status and trimester. Liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were developed and applied to the measurement of thyroid hormones, vitamin D metabolites, and vitamin D-binding protein (VDBP). Copper, selenium, and zinc measurements were conducted by inductively coupled plasma dynamic reaction cell MS. Thyroid stimulating hormone (TSH), thyroglobulin (Tg), and thyroglobulin antibody concentrations were analyzed using immunoassays and LC-MS/MS (Tg only). RESULTS: Certified values for thyroxine and triiodothyronine, reference values for vitamin D metabolites, VDBP, selenium, copper, and zinc, and information values for reverse triiodothyronine, TSH, Tg, and Tg antibodies were assigned. Significant differences in serum concentrations were evident for all analytes across the four levels (p≤0.003). TSH measurements were significantly different (p<0.0001) among research-only immunoassays. Tg concentrations were elevated in research-only immunoassays vs. Federal Drug Administration-approved automated immunoassay and LC-MS/MS. Presence of Tg antibodies increased differences between automated immunoassay and LC-MS/MS. CONCLUSIONS: The analyte concentrations' changes consistent with the literature and the demonstration of matrix interferences in immunoassay Tg measurements indicate the functionality of this material by providing a relevant matrix-matched reference material for the different stages of pregnancy.


Assuntos
Selênio , Oligoelementos , Biomarcadores/sangue , Cromatografia Líquida , Cobre , Feminino , Humanos , Gravidez , Espectrometria de Massas em Tandem , Tireoglobulina/sangue , Glândula Tireoide , Tireotropina , Oligoelementos/sangue , Vitamina D/sangue , Vitaminas , Zinco
8.
Anal Bioanal Chem ; 410(4): 1265-1278, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29222652

RESUMO

A Standard Reference Material (SRM) of seaweed, SRM 3232 Kelp Powder (Thallus laminariae) has been developed to support food and dietary supplement measurements in compliance with the Food Safety Modernization Act (FSMA) and the Dietary Supplement Health and Education Act of 1994 (DSHEA). The material was characterized for nutritional minerals, arsenic species, isomers of vitamin K1, proximates, and toxic elements. Kelp is a rich source of vitamins and minerals, and it is an excellent source of dietary iodine. Kelp also contains a large amount of arsenic, which is toxic as inorganic species but much less so as organic species. To capture the dietary profile of kelp, certified values were issued for As, Ca, Cd, Cr, Cu, Fe, Hg, I, K, Mg, Mn, Mo, Na, Pb, and Zn. Reference values for proximates were assigned. For the first time, a certified value for iodine, reference values for isomers of vitamin K1, and reference values for arsenic species including arsenosugars were assigned in a seaweed. SRM 3232 fills a gap in Certified Reference Materials (CRMs) needed for quality assurance and method validation in the compositional measurements of kelp and similar seaweeds used as food and as dietary supplements. Graphical Absract Arsenic species and isomers of vitamin K1 were determined in the development of SRM 3232 Kelp Powder (Thallus laminariae).


Assuntos
Kelp/química , Pós , Cromatografia Líquida , Padrões de Referência , Espectrometria de Massas em Tandem
9.
J AOAC Int ; 100(5): 1260-1276, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28863788

RESUMO

Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.


Assuntos
25-Hidroxivitamina D 2/sangue , Análise Química do Sangue/normas , Humanos , National Institutes of Health (U.S.) , Controle de Qualidade , Estados Unidos , Vitamina D
10.
J AOAC Int ; 100(5): 1277-1287, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28847346

RESUMO

Until recently, the Vitamin D External Quality Assessment Scheme (DEQAS) assessed the performance of various assays for the determination of serum total 25-hydroxyvitamin D [25(OH)D] by using a consensus mean based on the all-laboratory trimmed mean (ALTM) of the approximately 1000 participants' results. Since October 2012, the National Institute of Standards and Technology (NIST), as part of the Vitamin D Standardization Program, has participated in DEQAS by analyzing the quarterly serum sample sets using an isotope dilution LC-tandem MS (ID LC-MS/MS) reference measurement procedure to assign an accuracy-based target value for serum total 25(OH)D. NIST has analyzed 90 DEQAS samples (18 exercises × 5 samples/exercise) to assign target values. The NIST-assigned values are compared with the ALTM and the biases assessed for various assays used by the participants, e.g., LC-MS/MS, HPLC, and several ligand-binding assays. The NIST-value assignment process and the results of the analyses of the 90 DEQAS samples are summarized. The absolute mean bias between the NIST-assigned values and the ALTM was 5.6%, with 10% of the samples having biases >10%. Benefits of the accuracy-based target values are presented, including for sample sets with high concentrations of 25(OH)D2 and 3-epi-25(OH)D3.


Assuntos
Análise Química do Sangue/normas , Vitamina D/análogos & derivados , Calcifediol , Cromatografia Líquida de Alta Pressão/normas , Humanos , Espectrometria de Massas em Tandem/normas , Estados Unidos , Vitamina D/sangue
11.
J AOAC Int ; 100(5): 1308-1317, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28741469

RESUMO

Six laboratories associated with the Vitamin D Standardization Program (VDSP) participated in an interlaboratory comparison of LC with tandem MS (MS/MS) methods for the determination of 24,25-dihydroxyvitamin D3 [24,25(OH)2D3] in human serum. The laboratories analyzed two different serum-based Standard Reference Materials (SRMs) intended for use in the determination of 25-hydroxyvitamin D and 30 samples from the Vitamin D External Quality Assessment Scheme (DEQAS). All laboratory methods for 24,25(OH)2D3 were based on isotope dilution LC-MS/MS; three of the methods used derivatization of the vitamin D metabolites before LC-MS/MS. Laboratory results were compared to the National Institute of Standards and Technology (NIST) results, which were obtained using their newly developed candidate reference measurement procedure for 24,25(OH)2D3. Laboratory results for the SRM samples varied in comparability to the NIST results, with one laboratory in excellent agreement (-1.6% mean bias), three laboratories at 10-15% mean bias, and the remaining laboratory at 36% mean bias. For the 30 DEQAS samples, the mean bias for the five laboratories ranged from 6 to 15%; however, the SD of the bias ranged from 8 to 29%. As a result of this intercomparison study, one laboratory discovered and corrected a method calculation error and another laboratory modified and improved their LC-MS/MS method.


Assuntos
24,25-Di-Hidroxivitamina D 3/sangue , Análise Química do Sangue/normas , Ensaio de Proficiência Laboratorial , Cromatografia Líquida/normas , Humanos , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Vitamina D
12.
J AOAC Int ; 100(5): 1304-1307, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28492142

RESUMO

Vitamin D is an important nutrient for many areas of human health and well-being, including improved bone strength, muscle movement, cognitive function, and immune health. The National Institute of Standards and Technology, in collaboration with the National Institutes of Health Office of Dietary Supplements, has developed SRM 3532 Calcium-Containing Solid Oral Dosage Form to help address the analytical challenges seen by the dietary supplement communities for the determination of vitamin D3 (cholecalciferol) and elements. Described here is the process to assess the homogeneity and stability of the material, as well as the value assignment of the vitamin D3 levels.


Assuntos
Cálcio , Colecalciferol/análise , Suplementos Nutricionais/análise , Vitaminas/análise , Humanos , Padrões de Referência , Vitamina D
13.
Anal Bioanal Chem ; 409(4): 949-960, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27832301

RESUMO

Two independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. Graphical Abstract Separation of six isoflavone aglycones and glycosides found in Standard Reference Material (SRM) 3236 Soy Protein Isolate.


Assuntos
Cromatografia Líquida/métodos , Isoflavonas/análise , Alimentos de Soja/análise , Espectrofotometria Ultravioleta/métodos , Isótopos , Espectrometria de Massas , Espectroscopia de Prótons por Ressonância Magnética , Padrões de Referência
14.
J AOAC Int ; 98(6): 1483-90, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26651559

RESUMO

The characterization of marker components in botanical materials is a challenging task, and the increased consumption of botanicals and dietary supplements demands a greater understanding of the associated health benefits and risks. In order to successfully acquire and compare clinical results and correlate health trends, accurate, precise, and validated methods of analysis must be developed. Presented here is the development of a quantitative method for the determination of soy isoflavones (daidzin, glycitin, genistin, daidzein, and genistein) using LC-particle beam/electron ionization-MS (LC-PB/EIMS). An internal standard (IS) approach for quantitation with 7-hydroxy-4- chromone as the IS compound was used, with response factors for each individual isoflavone obtained from calibrant solutions. The results from this method were compared with the certified and reference values for National Institute of Standards and Technology (NIST) SRM 3238 Soy-Containing Solid Oral Dosage Form to demonstrate that the method was in control. Results obtained using LC-PB/EIMS were consistent with the NIST certified or reference values and their uncertainties for all five isoflavones, demonstrating that the LC-PB/EIMS approach is both accurate and precise when used for the determination of the target isoflavones in soy-containing dietary supplement finished products while simultaneously providing structural information.


Assuntos
Cromatografia Líquida/métodos , Isoflavonas/análise , Alimentos de Soja/análise , Espectrometria de Massas por Ionização por Electrospray/métodos
15.
J AOAC Int ; 96(5): 925-32, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24282927

RESUMO

Increased consumption of dietary supplements brings about important requirements of analytical methods to allow accurate and precise measurements of the chemical composition of these botanical materials. Presented here is the isoflavone content in proposed National Institute of Standards and Technology standard reference materials (SRMs) determined by LC-particle beam/electron ionization MS. Botanical materials (soy, red clover, and kudzu) are characterized for the content of a suite of five isoflavones (puerarin, daidzein, genistein, formononetin, and biochanin A). These compounds are of interest due to correlations with certain health benefits. An RP chromatographic separation was first optimized using UV-Vis spectrophotometric detection. The LC output was then introduced to an electron ionization source using a particle beam interface on an Extrel Benchmark MS system. The separation was carried out using a commercial C18 column and a linear gradient using water and methanol (both containing 0.1% trifluoroacetic acid as mobile phases A and B, at a flow rate of 1.0 mL/min over 40 min. LOD values for the isoflavones were determined to be at the ng level. Quantitation was performed using an internal standard (IS) approach with 7-hydroxy-4-chromone as the IS compound. The levels of isoflavones in the botanical products were determined for the proposed SRMs.


Assuntos
Cromatografia Líquida/métodos , Glycine max/química , Isoflavonas/análise , Pueraria/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Trifolium/química
16.
Anal Bioanal Chem ; 405(25): 8171-84, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23877182

RESUMO

A novel approach to ambient desorption/ionization mass spectrometry (ADI-MS) is described, based on a recently developed liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source. The device is essentially unmodified relative to its implementation in elemental mass spectrometry, where the operational space is characterized by low operation power (<10 W) and low solution delivery rates (<50 µL min(-1)). In this implementation, the plasma is produced between a Ni anode and an electrolytic liquid (1 M HNO3) cathode flowing through a glass capillary that is angled towards the sample surface, at a distance of ~2 mm away. Analyte species can be desorbed/ionized from neat solution residues and complex solid samples. The ADI-LS-APGD source is mounted onto the source interface of a Thermo Finnigan LCQ Advantage Max quadrupole ion trap mass spectrometer without modifications to the instrument faceplate or ion optics. Described here is the initial evaluation of the roles of source geometry and working parameters, including electrolytic solution composition and plasma current, on the response of caffeine residues, with preliminary limits of detection based on the relative standard deviation of the spectral background suggested to be on the 10-pg level. Demonstrative spectra are presented for green tea extracts and raw leaves, coffee beans, a dried (raw) tobacco leaf, an analgesic tablet, and paper currency. Versatility is further revealed through the determination of components in common cigarette smoke. In each case, the spectra are characterized by (M + H)(+) species of the expected constituents. The capacity for a single source to perform both in solution and particulate elemental analysis (as shown previously) and ADI of molecular species is unique in the realm of mass spectrometry.


Assuntos
Cafeína/análise , Espectrometria de Massas/instrumentação , Analgésicos não Narcóticos/química , Pressão Atmosférica , Café/química , Eletrólitos/química , Desenho de Equipamento , Ibuprofeno/química , Íons/química , Limite de Detecção , Espectrometria de Massas/métodos , Folhas de Planta/química , Chá/química , Nicotiana/química
17.
J Am Soc Mass Spectrom ; 24(6): 975-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23463546

RESUMO

Presented here is a novel in-line solid phase extraction (SPE) method utilizing a capillary-channeled polymer (C-CP) fiber microcolumn prior to introduction to an electrospray ionization (ESI) source. The high permeability of the microcolumn allows for operation under syringe pump or HPLC driven flow, ultimately providing greater mass spectral clarity and accurate molecular weight determinations for different protein/buffer combinations. Studies presented here focus on the desalting of several target proteins from a standard phosphate buffered saline (PBS) matrix and a synthetic urine solution prior to ESI-MS determinations. In every case, responses for µM-level proteins in PBS improve from the situation of not permitting molecular weight determinations to values that are precise to better than ±10 Da, without internal standards, with relative improvements in the signal-to-background ratios (S/B) on the order of 3,000×. De-salting of a myoglobin-spiked (12 µM) synthetic urine results in equally-improved spectral quality.


Assuntos
Proteínas/isolamento & purificação , Extração em Fase Sólida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Modelos Químicos , Peso Molecular , Permeabilidade , Polímeros , Proteínas/análise , Proteínas/química , Cloreto de Sódio/química , Extração em Fase Sólida/instrumentação
18.
Analyst ; 138(4): 1098-106, 2013 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-23223274

RESUMO

Polypropylene (PP) capillary-channeled polymer (C-CP) fibers are applied for solid phase extraction (SPE) of proteins from aqueous buffer solutions using a micropipette tip-based format. A process was developed in which centrifugation is used as the moving force for solution passage in the loading/washing steps instead of the previously employed manual aspiration. The complete procedure requires ~15 minutes, with the number of samples run in parallel limited only by the capacity of the centrifuge. The method performance was evaluated based on adsorption and elution characteristics of several proteins (cytochrome c, lysozyme, myoglobin, and glucose oxidase) from 150 mM phosphate buffered saline (PBS) solutions. Protein concentration ranges of ~2 to 100 µg mL(-1) were employed and the recovery characteristics determined through UV-Vis absorbance spectrophotometry for protein quantification. The protein loading capacities across the range of proteins was ~1.5 µg for the 5 mg fiber tips. Average recoveries from PBS were determined for each protein sample; cytochrome c ~86%, lysozyme ~80%, myoglobin ~86%, and glucose oxidase ~89%. Recoveries from more complex matrices, synthetic urine and synthetic saliva, were determined to be ~90%. A 10× dilution study for a fixed 1 µg protein application yielded 94 ± 3.2% recoveries. The C-CP tips provided significantly higher recoveries for myoglobin in a 150 mM PBS matrix in comparison to a commercially available protein SPE product, with the added advantages of low cost, rapid processing, and reusability.


Assuntos
Tubo Capilar , Polipropilenos/química , Extração em Fase Sólida/métodos , Soluções/análise , Soluções Tampão , Mioglobina/análise , Mioglobina/química , Polímeros/química , Soluções/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...